Control Panel System 42

The System 42 has been developed from the popular System 42 (S) specifically for particularly large projects. It is suitable for projects where the client wants to control the Fire/Smoke dampers from more than one location and minimises cable installation cost by reducing the necessity to run all of the control loops back to one main panel.

The System 42 is a purpose-made damper control system which operates via an RS 485 loop signal from each damper decoder to the main panel(s), and can have up to 8 master control panels networked together via a RS232 signal connected to each panel.


Product Information

  • Addressable loop system
  • Bi-directional communication
  • Programmed smoke control strategy
  • Building Management System (BMS) communication link
  • Activation of extract fans
  • Fireman's override control
  • On-site commissioning
  • Each system is bench tested before despatch.
  • Monitors and controls up to 504 dampers per panel (max of 4032 dampers per system)
  • Up to 120 fire alarm/override control inputs per panel (max of 960 inputs per system)
  • Addressable loop system
  • 4 loops per panel (max of 32 loops per system)
  • Up to 23,000 outputs available for damper indication, remote alarm and faults
  • Bi-directional communication
  • Programmed smoke control strategy
  • Building Management System (BMS) communication link
  • Fireman's override control at panel
  • Flush or surface panel mounting panel
  • 240 Vac/1 ph./50 Hz. supply to main panel
  • 240 Vac/1 ph./50 Hz supply to damper decoders via local distribution board as standard (24Vac options on request)
  • Test switch on damper decoders to facilitate local testing of the damper operation
  • On-site commissioning

SPF Efficiency Information

Advanced Air damper control systems have been, and continue to be used, on a variety of different projects, including extensively on both new build and refurbishment Hospital projects.

When using the Advanced Air addressable system 42, you can be assured that with its true bi-directional communication, control and monitoring of the installed equipment can be achieved at all times. Maintenance or replacement of any damper or fan decoder is quick and simple. By using a ‘plug and play’ method, replacement decoders can be sent to site pre-programmed for installation by the Hospitals maintenance team. Eliminating the need for costly engineering visits.

A full technical description of the system components and requirements is available separately.

Technical Advice

For further details and guidance on designing a system incorporating an Advanced Air addressable control panel and network, please contact the Projects Department.

Typical LCD screen display.

Screen size is 120mm x 90mm

Main Control Panel

The main standard panel is 350mm wide x 600mm high x 120mm deep, constructed from galvanised mild steel with a textured polyester powder finish.

The panel has a glass lockable front door and comes as a surface enclosure complete with flush mounting kit for optional on-site installation.

Decoders

The decoder is a small metal box, 200mm wide x 150mm high x 80mm deep. One of many connected in a loop in the system. The decoder controls the status of dampers or fans.

You may also like to consider

2590 300 deg C for 120 Mins High Temperature Smoke Dampers

The 2590 smoke damper has been designed to operate at 300°C for 2 hours to allow the extraction of smoke and toxic fumes during fire conditions.

more details